pgebanner

Fuse Disconnector Switch

  • J Type Heavy Duty Fuse Cut Out Base / LV Fuse Switch Disconnector

    J Type Heavy Duty Fuse Cut Out Base / LV Fuse Switch Disconnector

    J Type Fuse Cut Out is mainly used for line overload and short-circuit protection(gG/gL) in electrical devices,and can be derived for short-circuit protection(aR) and motor short-circuit protection(aM) for semiconductor equipment and complete sets of devices. J type fuse cut out base 400A is industry standard design,Designed with ease of use and simplicity in mind,this pole mount able fuse cut out is the ideal method of providing rural dwellings with a safe,protected and reliable low voltage ...
  • APDM Pole Mounted Fuse switch Disconnector For Line Protection

    APDM Pole Mounted Fuse switch Disconnector For Line Protection

    APDM fuse switch it is used either as an operation or protection device for LV line.It is designed to be used with NH 1-2 or 3 size fused offering a maximum of 630 Amps of line protection without blades. In case blades are used ,the maximum switching load would be 800A. It is manu-factured in reinfored fiberglass polyamide and fulfills all the necessary requirements for outdoor installation and operation. In the APDM model the connection is made with connectors suitable for aluminum and coppe...
  • HRC bar isolating switch with 160A fuse switch disconnector

    HRC bar isolating switch with 160A fuse switch disconnector

    HR17 Fuse-switch Disconnector is applied to under Rated Voltage 690V. The main current is 160A to 630A.It is mainly used as power switch, isolator switch and  emergency switch in power system. Assorted fuse links: NH00 for 160A, NH1 for 250A, NH2 for 400A and  NH3 for 630A Rated currents: 4, 6, 10, 16, 20, 25, 32, 35, 40, 50, 63, 80, 100, 125, 160, 200, 224, 250, 300, 315, 355, 400, 425, 500 and 630    fuse,fuse switch, HR17  fuse type isolation switch,rated insulating voltage AC800V.rated op...
  • HG2B Vertical Fuse Rail Switch Disconnector

    HG2B Vertical Fuse Rail Switch Disconnector

    Fuse-switch HG2B Disconnector is used below 690V of Rated Voltage. There is a 160A to 630A primary current. In a power system, it is mostly utilized as a power switch, isolator switch, and emergency switch. Assorted fuse links: NH00 for 160A, NH1 for 250A, NH2 for 400A and  NH3 for 630A Rated currents: 4, 6, 10, 16, 20, 25, 32, 35, 40, 50, 63, 80, 100, 125, 160, 200, 224, 250, 300, 315, 355, 400, 425, 500 and 630    fuse,fuse switch, Insulating voltage of the HG2B fuse type isolation switch i...